ecoSolv Technologies Inc.
consultation & implementation
unique products & technologies
|
|
Although Super Therm® can be applied by
non-professionals, SPI recommends using a SPI certified applicator.
Preparation:
Surface must be clean and completely dry, with no loose debris or particles, rust, dirt, oil, films or residues of any kind. SUPER THERM® will cover previous coatings if they are fully adhered to the surface
If over-coating an existing paint, make sure all gloss is removed from surface by sanding or minimum blast
Mechanically stir, as ceramics will tend to settle
Remove all filters from spray equipment
Application methods:
Airless or pot sprayed: tip size .029-.032; apply in one coat using crosshatch method
Roller: use 3/4" nap commercial roller; apply in two coats
Brush: use soft bristle brush; apply in two coats
Vertical surfaces should be applied in two coats
Applied rate:
100 sq. ft./gal. (9 sq.m./gal.)
Film thickness:
Wet: 14-16 mils (350-400 microns)
Dry: 8-10 mils (200-250 microns)
Temperature:
50 degrees F (10 degrees C) - 194 degrees F (90 degrees C)
72 degrees F (22 degrees C) best
Dry times:
1 hour to touch at 72 degrees F (22 degrees C)
4 hours to recoat
Full cure:
14 – 21 days
Limitations:
Not suitable for underwater use of any kind
Not recommended as the only fire protection material to be used in residential or industrial construction
Do not use as a stand-alone floor coating
Do not used directly on food preparation surfaces
Super Therm® can be tinted, but darker colors will reduce effectiveness
| |